Home Products Suppliers Links Contacts

Radiant Floor Heating

Zmesh is a UL/CSA listed, low-voltage element in either a 9 or 12 inch wide bronze mesh, similar to screen door material. Because of its low profile (only 1/16th of an inch) installing any floor surface over Zmesh is simple. Unlike with hydronic systems (water/glycol mix), no cement or under floor support is required. Zmesh is the best radiant floor warming solution for under carpet, hardwood, tile, marble, slate, linoleum, and vinyl installations available. The heat density of ZMesh is dependent on the spacing between adjacent runs and the length of element delivering from 5 to 12 watts per lineal foot.

Heatizon ZMesh low voltage in floor heat products are solid state; they have no moving parts to wear out. Yearly technician visits for cleaning and servicing are not required; there are no radiator intrusions into your living space and insurance for furnace oil spills are not a concern. Quality floor heating elements are the longest lasting available and are backed by industry leading warranties. Completely eliminate winter heating maintenance with the most reliable radiant floor heating source available.

ZMesh can be stapled and nailed through for easy installation. In addition, surface build up is not necessary with ZMesh. Install it directly under hardwood flooring, carpet, tile, linoleum or vinyl, and marble. It is zone controlled by a computer/transformer that mounts on a wall in a closet or in a basement. A 7-day programmable controls either room or floor temperature.

Utilizing 100% of the energy it draws to create heat, Heatizon systems are incredibly energy efficient. By automatically radiating heat to the floors and rooms, families are comfortable at lower thermostat settings. The systems come complete with programmable controllers and   material package for all new construction or re-model projects



"See Installation Videos"

 

TUFF CABLE SYSTEMS LOW VOLTAGE

Tuff Cable Floor Warming or Primary Space Heating Systems. Tuff Cable is a durable 10 gauge insulated and coated copper element that is chemical and Gasoline resistant. It is designed to be installed in concrete, tile mortar bed or thin set. Tuff Cable heating system is available to meet customer requirements in low voltage heating designs.

Utilizing state of the art components and low-voltage electricity, our systems are virtually maintenance free, and are safe and efficient in operation. Tuff Cable has a 25 year manfactures warranty and is engineered to provide simple and problem-free solutions. Tuff cable low-voltage products have been in usefor more than 30 years.

 


IN FLOOR RADIANT HEAT TUFF CABLE

 

Electrical Thermal Storage (ETS) Radiant Floor Heat Systems
CONTACT POWERPLANT SUPPLY FOR DETAILS

Electric radiant floor heat systems are similar to other radiant floor heat systems, up to the point of heating the floor. Other systems produce heat on demand like furnace boilers and hot air circulation systems. Electrical radiant floor heat may be integrated into an electric thermal storage system (ETS). Using electric energy to heat a thermal storage mass like a concrete floor slab, electrical radiant floor heat qualifies for reduced time of day rates.

There are considerations when designing an electrical thermal storage system utilizing a concrete floor slab. Power companies do not provide specific design and/or installation instructions beyond installing the equipment used to control the time of day records.

There are some basics to follow which do not add cost to the building that result in significant energy savings. Home owners are making ETS systems a design priority. Lower energy cost with all the benefits of electrical radiant floor heat are an attractive benefit.  For more information on radiant floor systems, contact Power Plant Supply Co; sales@powerplantsupplyco.com.

 

Suggestions for Electrical Thermal Slab Storage Design

A 4 inch slab-on-ground inside the insulated building envelope, with a minimum of 2 inch of rigid insulation underneath, offers substantial concrete thermal mass retention qualities. Cost for a thermal storage 4 inch slab is normally absorbed in the basic design of the building with no extra outlays. For ETS time of day consideration, the basement or slab must be thermally heated with electrical energy. Consult a qualified industry source for more detailed information sales@powerplantsupplyco.com.

When considering the type of heating cable to use: low voltage heat systems or high voltage heat cables may be utilized. Of special note if high voltage cables are considered; *by code high voltage 120/240v etc. cables must be isolated by covering them with a minimum of two inches of concrete in the slab. A more durable 120/240v cable with better jacket and moisture protection qualities are available at Power Plant Supply Co. Upper floor levels can be heated with high voltage electrical floor cables only where concrete over pours can be used to cover high voltage cables.

Less restricted low voltage systems may be installed on upper floors instead of high voltage cable. Concrete floors and the added floor support cost are eliminated.

Low voltage floor heating systems: Low voltage floor heat systems convert line voltage in the control unit to between 8-30 volts of electricity and this low current is then sent through the heating elements. Resistance in the elements heat the floor at controlled temperatures. The low-voltage heating elements available are ZMesh or Tuff Cable, depending on the installation. The heat created radiates from the element through the floor and continues to warm other objects in the room. None of the heat produced is wasted before being fully utilized.

Floor covers like tiles for example are installed over the grout as per normal installation. Efficient low voltage cables may be imbedded just below the slab surface, or placed in a tile mortar bed or thin set on the slab surface.

Low voltage ZMesh element screen may be laid directly on the slab and flooring installed over the ZMesh. Low voltage radiant floor heat radiate heat like the sun shining through a window; warming floors and the room, while storing thermal energy in the concrete for greater energy efficiency.

Low voltage cable does not require a deep burial in concrete for protection from high voltage effects. Low voltage floor heating cable may be imbedded in a tile grout thin set, or on a slab or wood sub floor. Upper Floors may also be heated with low Voltage ZMesh element, which is placed on the sub floor and hardwood flooring or other floor coverings installed over the mesh. Upper concrete floors with all the associated cost and support structures are not necessary when utilizing low voltage systems.

In general, heat loss should be calculated for each project; the better insulated the home the more efficient a floor radiant heating system will be. Efficient heating and energy storage with electric power provides comfort and savings superior to other forms of heating. Appropriate capacity selected guidance and total installation systems are available from Power Plant Supply Co. sales@powerplantsupplyco.com.

 

Time of day electrical rates utilizing; Electrical Thermal Storage (ETS) Radiant Floor Heat Systems
For greater detail and assistance contact Power Plant Supply

Time of day rate is an optional rate available to customers utilizing floor electrical radiant heat. Customers who qualify for the rate can take advantage of low-cost electricity by focusing on the “time-of-day” the energy is used. To qualify for use with the TOD rate, Electrical thermal storage system must be utilized, for example concrete slab thermal storage is an acceptable system for TOD.

To encourage customers to use the majority of their electricity during "off-peak" times, In Nova Scotia for example, Nova Scotia Power offers the TOD rate during low cost "off-peak" times for thermal storage customers; the heat is release later in the day when cost are higher. Thermal storage may be utilized by using various storage methods; an insulated basement slab or insulated slab-on-ground is recognized as an available thermal storage mass.

The time-of-day (TOD) schedule is easy to follow and is automatically recorded for the customer. In some cases power used on all weekends or holidays for example and during night time hours, 11:00 p.m. to 7:00 a.m., is charged at the "off peak" rate; approximately half of the regular rate.

A home with electrical radiant floor heat and a ETS concrete slab system qualifies for "off-peak" time charges: including, power drawn/stored for heat, water heaters, dryers, washers, snow melt systems etc.

In Canada for all in-floor heating, floor heating, heated floors, electric floor heating, floor warming, room heating, warm floor, radiant floor, radiant heating, electric radiant heating, heated ramps, roof de-icing, gutter deicing, snow melting, snowmelting, snow-melting, heated driveway, pipe tracing, heat trace, heat tracing, snow removal, automatic snow removal, tank heating Power Plant Supply Co has convenient shipping warehouse locations in Canada, to serve customers in Ontario, ON, Quebec, QC, Atlantic Canada, including New Brunswick, NB, PEI, Nova Scotia, NS, Newfoundland & Labrador, NL, British Columbia, BC, Alberta, AB, Manitoba, Man, Saskatchewan, SK, Nunavut, Northwest Territories, NWT, Yukon. Next day Air or convenient ground to major cities including Vancouver, Calgary, Edmonton, Fort McMurray, Winnipeg, Yellowknife, Thunder Bay, Hamilton, Toronto, Ottawa, Montreal, Quebec City, Saint John, Moncton, Fredericton, Charlottetown, Halifax, Sydney, Corner Brook, St John's.

www.powerplantsupplyco.com